BRSCB - CATALYST/AQUARIUS PLAS-TITE II 2518, 192518

  • MSDS: BRSCB
  • Manufacturer: D B A PRODUCTS COMPANY INC
  • Product Name: CATALYST/AQUARIUS PLAS-TITE II 2518, 192518
  • National Stock Number: 8040-00N016928
Product Identification

Product ID:CATALYST/AQUARIUS PLAS-TITE II 2518, 192518
MSDS Date:09/15/1989
FSC:8040
NIIN:00N016928
MSDS Number: BRSCB

Responsible Party
D B A PRODUCTS COMPANY INC
22 SKOKIE HIGHWAY
LAKE BLUFF, IL 60044
US

Emergency Phone: 708-234-8100

Info Phone: 708-234-8100

Cage: 23693

Contractor
D B A PRODUCTS CO INC
LAKE BLUFF, IL 60044-1711 US

Telephone: 312-234-8100

Cage: 23693

Ingredients

ETHYLENIMINE (SARA III)

CAS: 151-56-4

RTECS: KX5075000

OSHA PEL SEE 1910.1012

ACGIH TLV: S, 0.5 PPM; 9293

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:YES
Health Hazards Acute and Chronic:ACUTE/CHRONIC:INGEST:UNKNOWN.
INHAL:MAY CAUSE SEVERE NOSE AND THROAT IRRITATION. EYE:MAY CAUSE
SEVERE IRRITATION. SKIN:MAY CAUSE SEVERE IRRITATION.
Explanation of Carcinogenicity:ETHYLENAMINE:OSHA REGULATED CARCINOGEN,
29 CFR 1910.1012, O1J-1, 1992.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:CALL POISON CONTROL CENTER, HOSPITAL EMERGENCY ROOM OR
MD IMMED. INHAL:REMOVE TO FRESH AIR IMMED. IF BREATHING HAS
STOPPED, GIVE ARTF RESP. KEEP WARM & QUIET. GET MD. EYE:FLUSH WITH
LARGE AMOUN TS OF WATER, LIFTING UPPER & LOWER LIDSOCCASIONALLY.
CONTINUE FOR AT LEAST 15 MINS. GET MD. SKIN:IMMED FLUSH W/LRG AMT
OF WATER. REMOVE CONTAM CLTHG AS WATER IS APPLIED. GET MD IF IRRIT
PERSISTS.

Fire Fighting

Flash Point Method:SCC
Flash Point:200F,93C
Extinguishing Media:USE CLASS B FIRE EXTINGS (CARBON DIOXIDE, ALL PURP
DRY CHEM OR ALCOHOL FOAM) DESIGNED TO EXTING FLAMM LIQ
FIRES.(SUPDAT)
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIP . WATER MAY BE INEFTIVE, BUT USE TO COOL EXPOSED
CNTNRS TO PVNT PRESS BUILDUP & AUTO-IGNIT (SUPDAT)
Unusual Fire/Explosion Hazard:DURING EMERGENCY CONDITIONS, OVEREXPOSURE
TO DECOMPOSITION PRODUCTS MAY CAUSE A HEALTH HAZARD. SYMPTOMS MAY
NOT BE IMMEDIATELY APPARENT. GET MD.

Accidental Release

Spill Release Procedures:WEAR NIOSH/MSHA APPROVED RESPIRATOR, EYE,
HAND, AND BODY PROTECTION APPROPRIATE FOR THE SIZE OF THE SPILL AND
EXPOSURE ENCOUNTERED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE LIKELY TO BE NEEDED. CLOSE
CONTAINER AFTER EACH USE. USE SUGGESTED PROTECTIVE EQUIPMENT
WHENEVER USING PRODUCT.
Other Precautions:DO NOT TAKE INTERNALLY.

Exposure Controls

Respiratory Protection:IF TLV'S LISTED ARE EXCEEDED, USE A PROPERLY
FITTED NIOSH/MSHA APPROVED RESPIRATOR WITH APPROPRIATE PROTECTION
FACTOR. REFER TO OSHA 29 CFR 1910.134 "RESPIRATORY PROTECTION".
Ventilation:MECHANICAL (GENERAL):PREFERRED.
Protective Gloves:SOLVENT IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EYE WASH AND SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY WITH SOAP & WATER BEFORE EACH
BREAK PERIOD AND AT THE END OF THE SHIFT.
Supplemental Safety and Health
EXTING MEDIA:POLYMER FOAM IS PREFERRED FOR LARGE FIRES. FIRE FIGHT
PROC:OR EXPLOSION WHEN EXPOSED TO EXTREME HEAT. IF WATER IS USED,
FOG NOZZLES ARE PREFERRED.

Chemical Properties

Boiling Pt:B.P. Text:>131F,>55C
Vapor Density:>1
Spec Gravity:1.07 (WATER=1)
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:SOLUBLE
Appearance and Odor:YELLOW LIQUID OF MEDIUM VISCOSITY.
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:KEEP AWAY FROM HEAT, SPARKS AND OPEN
FLAME.
Hazardous Decomposition Products:WHEN BURNED WILL PRODUCE SMOKE, CARBON
MONOXIDE AND CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS. RCRA CLASSIFICATION:AS PRODUCED THIS PRODUCT IS
NOT A WASTE. IF DISCARDED AS IS IT IS NOT CLASSIFIED AS HAZARDOUS
WASTE UNDER RCRA.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.